Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
600
|
900
|
1200
|
1500
|
1800
|
2100
|
2400
|
|
Standard
|
27
|
27
|
27
|
22
|
18
|
15
|
13
|
|
Heavy duty
|
41
|
41
|
41
|
34
|
28
|
23
|
20
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
600
|
900
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
4200
|
|
Standard
|
37
|
34
|
29
|
26
|
20
|
17
|
15
|
12
|
7
|
n/a
|
|
Heavy duty
|
52
|
21
|
43
|
35
|
29
|
25
|
22
|
19
|
13
|
7
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
600
|
900
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
4200
|
|
Standard Plus
|
37
|
34
|
29
|
26
|
20
|
17
|
15
|
12
|
7
|
n/a
|
|
Heavy duty
|
52
|
51
|
43
|
35
|
29
|
25
|
22
|
19
|
13
|
7
|
|
Extra Heavy Duty
|
69
|
69
|
66
|
57
|
49
|
45
|
42
|
36
|
21
|
13
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
600
|
900
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
4200
|
4800
|
|
Standard Plus
|
44
|
41
|
36
|
31
|
27
|
24
|
22
|
20
|
18
|
10
|
n/a
|
|
Heavy duty
|
61
|
61
|
53
|
45
|
38
|
35
|
32
|
27
|
21
|
15
|
9
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
600
|
900
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
4200
|
4800
|
|
Standard
|
69
|
69
|
66
|
57
|
49
|
45
|
42
|
36
|
21
|
14
|
11
|
|
Heavy duty
|
103
|
103
|
99
|
85
|
73
|
67
|
63
|
54
|
31
|
21
|
16
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
3900
|
4200
|
4500
|
|
Standard
|
180
|
180
|
180
|
180
|
159
|
118
|
77
|
61
|
49
|
41
|
|
Heavy Duty
|
185
|
185
|
185
|
185
|
165
|
123
|
82
|
66
|
54
|
46
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
3900
|
4200
|
4500
|
|
Standard
|
180
|
180
|
180
|
180
|
159
|
118
|
77
|
61
|
49
|
41
|
|
Heavy Duty
|
185
|
185
|
185
|
185
|
165
|
123
|
82
|
66
|
54
|
46
|
Safe working load at maximum span (Kn)
Minimum end bearing 250mm
Overall profile of lintels will suit shutter drops.
Furthest projection out of window/door should be set some 23mm back from channel guide so as not to obstruct path of shutter
|
to (mm)
|
1200
|
1500
|
1800
|
2100
|
2400
|
3000
|
3600
|
3900
|
4200
|
4500
|
|
Standard
|
190
|
190
|
190
|
190
|
169
|
128
|
87
|
71
|
59
|
51
|
|
Heavy Duty
|
195
|
195
|
195
|
195
|
174
|
133
|
92
|
76
|
64
|
56
|